The AGE pressurized electrolyzer
family is based on a patented alkali process which warrants
high efficiency, reliable operation and represents the state-of-the-art
commercially available today. Several installations, based
on this technology, are running continuously failure free
in the field for over 15 years. The operating parameters are
continuously supervised by a special control logic capable
of recognizing possible running defects and, if the case,
stopping and reverting the unit to a fail-safe condition in
case of malfunction. A control panel allows to operate the
machine in a very simple way through a touchscreen. The very
rugged and compact construction is suitable for equipment
transportation. Ease of operation makes this device usable
with a minimum of training thus reducing significantly set-up
and operation costs. Because of the very high security features
in the outdoor execution, the electrolyzer can be operated
in a non classified environment, i.e. it can be placed in
any room without the need to classify the ambient for electrical
installation with explosive gases.
The HQ device option delivers hydrogen gas with purity of
99.999% and dew point of - 50°C suitable for Fuel Cell
supply. The AGE family can be fabricated with 10 bar, 30 bar
or 200 bar gas output pressure without the need of compressors.
All electrolyzers of the AGE family shows an overall very
high efficiency. For special applications, like hydrogen production
from renewable energy sources, AccaGen has developed electrolyzers
with ultra high efficiency >85%. Moreover these devices
mounts electrodes designed to work with strong fluctuating
electrical currents, like usually happens in solar or wind
energy production systems, without suffering any electrode
degradation over time.
Standard Features
| Feature |
Dimension |
Unit/Condition |
| H2 output pressure |
10 |
bar |
| H2 purity (the balance is O2) |
99.9 |
% vol |
| H2 moisture content |
Saturated |
at P and T of delivery |
| O2 purity (the balance is H2) |
99.6 |
% vol |
| O2 moisture content |
Saturated |
at P and T of delivery |
| Electrolyte |
KOH |
|
| Installation |
Indoor - Classified environment |
Optional Features
| Feature |
Dimension |
Unit/Condition |
Option |
| H2 output pressure |
30 |
bar |
HP High Pressure |
| H2 output pressure |
200 |
bar |
VHP Very High Pressure |
| H2 purity |
99.999 |
% vol |
HQ High Quality |
| H2 moisture content |
-50 |
°C dew point |
HQ High Quality |
| Installation |
Indoor/Outdoor - non classified environment |
O Outdoor execution |
|